Respiratory dataset from PEEP study with expiratory occlusion
Outlined is a pressure, flow, volume, dynamic circumference, and EIT assessed aeration dataset from resting breathing with REO at increasing CPAP PEEP settings. Vapers, asthmatics, smokers, and otherwise healthy people were included in the trial. A trial was conducted to collect gauge pressure and flow from a venturi-based flow-meter, dynamic abdominal and thoracic circumference from rotary-encoder based tape measures, and aeration data from electrical impedance tomography (EIT). Data was collected from 80 adults, breathing with continuous positive airway pressure (CPAP) ventilation, under ethical consent from the University of Canterbury Human Research Ethics Committee (HREC 2023/04/LR-PS). In each subject’s recording the positive end expiratory pressure (PEEP) was increased from 4 to 12 cmH2O in 0.5 cmH2O increments, with data recorded for 30 seconds at each level.
| Source | PhysioNet |
|---|---|
| Access | Open access |
| Conditions | Asthma, Healthy Volunteers |
| Data type | physiological waveforms |
| Size | 19.6 GB |
| License | Creative Commons Attribution 4.0 International Public License |
| Citation | Respiratory dataset from PEEP study with expiratory occlusion (version 1.0.0). PhysioNet (2023). doi:10.13026/psrj-rw40 |
How to access
Go to the source page (PhysioNet) →
Papers using this dataset
3 papers use or cite this dataset. Most cited:
- Differential Respiratory Responses to Incremental Positive End-Expiratory Pressure Among Healthy Adults, Cigarette Smokers, Electronic Cigarette Users, and Individuals with Asthma. (dataset paper)
- Overview of Respiratory Sensor Solutions to Support Patient Diagnosis and Monitoring.
- Multimodal data driven machine learning approach for enhancing diagnostic accuracy and efficiency in pulmonary disease management within primary healthcare settings.
- Respiratory monitoring dataset, with rapid expiratory occlusions, over increasing positive airway pressure ventilation.
Compatible datasets
25 datasets could be combined with this one or used to validate a model trained on it:
- Autonomic Aging: A dataset to quantify changes of cardiovascular autonomic function during healthy aging
- SCG-RHC: Wearable Seismocardiogram Signal and Right Heart Catheter Database
- MIMIC-II Clinical Database
- Cerebral Vasoregulation in Elderly with Stroke
- PPG-DaLiA (PPG dataset for motion-compensated heart-rate estimation in Daily Life Activities)
- Cerebral Vasoregulation in Diabetes
- DREAMT: Dataset for Real-time sleep stage EstimAtion using Multisensor wearable Technology
- CCEP ECoG dataset across age 4-51 (OpenNeuro ds004080)
- NInFEA: Non-Invasive Multimodal Foetal ECG-Doppler Dataset for Antenatal Cardiology Research
- MIMIC-III-Ext-PPG benchmark dataset
- CGMacros: a scientific dataset for personalized nutrition and diet monitoring
- Fantasia Database
- Annotated dataset of post-ischemic ventricular tachycardia electrograms (ARGO)
- TARGET-MAP: Transcranial doppler AutoReGulation assessment of brain perfusion in nEurocritical patients for MAP optimization
- CPAP Pressure and Flow Data from a Local Trial of 30 Adults at the University of Canterbury
- Simulated Obstructive Disease Respiratory Pressure and Flow
- Respiratory and Pulse Oximetry Waveforms from Healthy Adults During Simulated Apnoea Events
- Wearable Physiological and Blood Pressure Measurements During Activities of Daily Living
- eICU Collaborative Research Database
- Predicting Mortality of ICU Patients: The PhysioNet/Computing in Cardiology Challenge 2012
- MIMIC-III Waveform Database Matched Subset
- INSPIRE, a publicly available research dataset for perioperative medicine
- Establishment of a Chinese critical care database from electronic healthcare records in a tertiary care medical center
- MIMIC-III Waveform Database
- HiRID, a high time-resolution ICU dataset
FDA submissions
No FDA submissions linked to this dataset yet.