Datasets › General Anatomy

Samples of MR Images

These magnetic resonance angiography (MRA) images show coronal slices acquired from consecutive anteroposterior positions within the torso. The study was performed on a 1.5T General Electric (GE) Signa imaging system with gadolinium-contrast-enhancement for visualization of the cardiopulmonary vasculature. The pulse sequence used was a 3D time-of-flight fast spoiled gradient recalled acquisition in steady state (FSPGR, TR=6.3, TE=1.4, NEX=1, FOV = 40cm, slice thickness = 1.2mm).

SourcePhysioNet
AccessOpen access
ConditionsGeneral Anatomy
Data typemri
Size74.2 MB
LicenseOpen Data Commons Attribution License v1.0
CitationSamples of MR Images (version 1.0.0). PhysioNet (2001). doi:10.13026/C2001G

How to access

Open access: no account needed. Download from the project page ("Download the ZIP file"), or mirror it with wget -r -N -c -np https://physionet.org/files/images/1.0.0/

Go to the source page (PhysioNet) →

Papers using this dataset

30 papers use or cite this dataset. Most cited:

All papers in the interactive catalog

Compatible datasets

No compatible datasets identified yet.

FDA submissions

No FDA submissions linked to this dataset yet.

Conditions

Open in the interactive catalog