UK Biobank Physical Activity Monitor (Axivity AX3 wrist accelerometry, Category 1008) with linked hospital records
Wrist-worn Axivity AX3 triaxial accelerometer data collected at 100 Hz (±8 g) over 7 continuous days from ~100,000 UK Biobank participants between June 2013 and January 2016, with quarterly seasonal repeat wears added from 2018. Raw .cwa files plus derived fields (average acceleration, wear time, activity-segment time series, sleep/physical activity summaries) are available. Because UK Biobank is linked to Hospital Episode Statistics (OPCS-4 operative procedure codes and ICD-10 diagnoses), death registry and primary care records, the accelerometry can be aligned to surgical episodes and to incident neurological outcomes such as stroke, dementia/delirium and epilepsy — making it the largest resource for pre/post-operative accelerometry-based risk modelling.
| Source | UK Biobank Data Showcase |
|---|---|
| Access | Data use agreement |
| Conditions | Stroke, Dementia, Delirium, Epilepsy, Gait and Mobility Impairment, Postoperative Complications |
| Data type | imu |
| Format | cwa, csv, tsv |
| Size | Raw .cwa files ~ hundreds of TB in total; derived summaries far smaller (accessed via UK Biobank Research Analysis Platform) |
| Subjects | ~103,000 participants with accelerometer data (of 502,000 in the cohort) |
| Labels | Linked hospital inpatient records (ICD-9/10 diagnoses, OPCS-4 surgical procedure codes), death registry, cancer registry, primary care data; derived accelerometer summary variables (overall acceleration average, wear-time quality flags, activity type time series) |
| License | UK Biobank Material Transfer Agreement / Access Terms (approved research use only) |
| Citation | Doherty A, Jackson D, Hammerla N, et al. Large Scale Population Assessment of Physical Activity Using Wrist Worn Accelerometers: The UK Biobank Study. PLoS ONE 2017;12(2):e0169649. |
How to access
Go to the source page (UK Biobank Data Showcase) →
Papers using this dataset
1,715 papers use or cite this dataset. Most cited:
- Large Scale Population Assessment of Physical Activity Using Wrist Worn Accelerometers: The UK Biobank Study. (dataset paper)
- The UK Biobank resource with deep phenotyping and genomic data.
- Primary care-led weight management for remission of type 2 diabetes (DiRECT): an open-label, cluster-randomised trial.
- Genome-wide association analyses of chronotype in 697,828 individuals provides insights into circadian rhythms.
- Assessment of Bidirectional Relationships Between Physical Activity and Depression Among Adults: A 2-Sample Mendelian Randomization Study.
- Genome-wide association study identifies genetic loci for self-reported habitual sleep duration supported by accelerometer-derived estimates.
- Physical activity and risks of breast and colorectal cancer: a Mendelian randomisation analysis.
- Daily energy expenditure through the human life course.
- Estimating sleep parameters using an accelerometer without sleep diary.
- Genome-wide association study of habitual physical activity in over 377,000 UK Biobank participants identifies multiple variants including CADM2 and APOE.
Compatible datasets
25 datasets could be combined with this one or used to validate a model trained on it:
- Hospitalized patients with heart failure: integrating electronic healthcare records and external outcome data
- INSPECT: A Multimodal Dataset for Pulmonary Embolism Diagnosis and Prognosis
- Clinical data from the MIMIC-II database for a case study on indwelling arterial catheters
- VitalDB, a high-fidelity multi-parameter vital signs database in surgical patients
- Bridge2AI-Voice: An ethically-sourced, diverse voice dataset linked to health information
- Stroke Outcome Optimization Project (SOOP) (OpenNeuro ds004889)
- MIMIC-III Clinical Database
- Framingham Heart Study (FHS) via NHLBI BioLINCC
- Aphasia Recovery Cohort (ARC) Dataset (OpenNeuro ds004884)
- An open presurgery MRI dataset of people with epilepsy and focal cortical dysplasia type II (OpenNeuro ds004199)
- Precise vs. Approximate Numeracy in Stroke Participants (OpenNeuro ds006533)
- Pre-Post rehabilitation fMRI data of post-stroke patients. (OpenNeuro ds003999)
- fMRI data for: Multimodal single-neuron, intracranial EEG, and fMRI brain responses during movie watching in human patients (OpenNeuro ds004798)
- Open diffusion MRI and connectivity data for epilepsy and surgery: The IDEAS II release (OpenNeuro ds007401)
- Epilepsy-iEEG-Multicenter-Dataset (OpenNeuro ds003029)
- PROBE iEEG (OpenNeuro ds003078)
- Dataset Clinical Epilepsy iEEG to BIDS - RESPect_longterm_iEEG (OpenNeuro ds003848)
- WIRED ICM Sample Dataset - Workshop on Intracranial Recordings in Humans, Epilepsy, DBS (OpenNeuro ds004993)
- Aurora-BP Study Dataset (wearable tonometry, PPG, ECG with in-lab and ambulatory blood pressure)
- PADS - Parkinsons Disease Smartwatch dataset
- DREAMT: Dataset for Real-time sleep stage EstimAtion using Multisensor wearable Technology
- In-hospital physical activity measured with a new Bosch accelerometer sensor system
- BIG IDEAs Lab Glycemic Variability and Wearable Device Data
- BarKA-MS: Fitbit and Fatigue Data of People with Multiple Sclerosis during and after Rehabilitation
- CovIdentify Dataset
FDA submissions
No FDA submissions linked to this dataset yet.